The ultrapure water system uses municipal tap water as its feedwater source. After entering the raw water tank, the feedwater undergoes ultrafiltration pretreatment, followed by first- and second-stage reverse osmosis for desalination. The RO permeate then enters the intermediate water tank before being further treated by the EDI and polishing mixed-bed systems for deep demineralization, meeting the ultrapure water quality requirements of the production line.
The treated water meets the ultrapure water quality requirements of the production line.
Raw Water Tank → UF (Ultrafiltration) System → First- and Second-Stage RO (Reverse Osmosis) System → Intermediate Water Tank → EDI (Electrodeionization) Unit → Polishing Mixed-Bed Unit → Product Water